Fleet management may stop responding as timestamps of the last logs received accumulate and exceed available heap memory
| Reference ID | COM-23574 |
|---|---|
| Date Published | October 15, 2026 |
| Affected Products | Fleet |
| Affected Versions | v2.12.1 and earlier |
| Status | Under Development |
| Fix Version | v2.12.2 |
| Description | Fabric-enabled SIEMs connected to Fleet send a report every five minutes with the timestamp of the latest logs received from each log source. Fabric Proxy (ZooKeeper) keeps these reports for 24 hours. Every five minutes, Fleet management retrieves all 24 hours of reports from every SIEM, even though it only needs the latest one. On SIEMs with many log sources, this data can exhaust Fleet management's heap memory and cause all Fleet management endpoints to stop responding until the service is restarted manually. If your deployment is affected by this issue, you may see the following signs:
|
| Workaround |
|