Alert rules may stop triggering when dashboards or alerts use timechart with long intervals

Avatar Kripa Thapa
November 17, 2026 06:37
Follow
Reference ID
LP-78922
Date Published November 17, 2026
Affected Products Guardsix SIEM
Affected Versions 7.6.0 and later
Status
Under Development
Fix Version 8.0.0
Description

If your dashboard widgets or alert rules use timechart with a long every interval, such as every 1 day over a 7-day time range, alert rules may stop triggering.

If your deployment is affected by this issue, you may see the following:

  • Alert rules stop generating incidents, even though logs are still being collected.

  • Heartbeat alerts, if you use them to monitor alerting, also stop generating incidents.

  • The problem starts after an upgrade from v7.6.0, with dashboards and alert rules that ran without problems before.

From v7.6.0, these searches process a full interval of data, such as a day, at a time and can take longer than 90 minutes; when that happens, Guardsix SIEM starts the search again without stopping the first one, and the extra copies use up the capacity that alert searches need. Any other aggregation search that takes longer than 90 minutes can cause the same issue.

Workaround
Contact Support.

Comments

Article is closed for comments.

Related articles

  • Label conditions inside aggregation functions or the search command fail to match or return incorrect counts
Was this article helpful? 0 out of 0 found this helpful
Privacy policy    EULA    Terms of service   
Copyright © , Guardsix. All rights reserved.

Note: We use cookies that are essential for the smooth functioning of our website.